Consideration is given to the evaluation of several simple mathematical models which represent magnetic saturation in a synchronous machine. Particular attention is paid to quadrature axis saturation in conjunction with an automatic voltage regulator and either a slow electro-magnetic exciter or a fast thyristor exciter. Calculated transient response results are compared in order to evaluate both the accuracy and computational economy of each saturation model.
| Original language | English |
|---|---|
| Pages (from-to) | 235-243 |
| Number of pages | 9 |
| Journal | Transactions of the South African Institute of Electrical Engineers |
| Volume | 73 |
| Issue number | pt 11 |
| Publication status | Published - 1982 |