In this paper, a robust model based control has been studied for BTX (Benzene-Toluene-Xylene) separation system in a dividing wall column. Compositions of the three products are indirectly controlled by regulating the corresponding temperatures by manipulating reflux rate, side-stream flow rate, and reboiler heat duty. It has been observed that the model based control shows good performance even in the presence of ± 10% change in the feed flow rate, feed composition, and liquid split factor in comparison to conventional controllers. This controller has less settling time (almost 1.5 hrs) as compared to PI controller (approximately 3-4 hrs).

Original languageEnglish
Title of host publication2013 International Conference on Control Communication and Computing, ICCC 2013
PublisherIEEE Computer Society
Pages107-112
Number of pages6
ISBN (Print)9781479905751
DOIs
Publication statusPublished - 2013
Externally publishedYes
Event2013 International Conference on Control Communication and Computing, ICCC 2013 - Trivandrum, Kerala, India
Duration: 13 Dec 201315 Dec 2013

Publication series

Name2013 International Conference on Control Communication and Computing, ICCC 2013

Conference

Conference2013 International Conference on Control Communication and Computing, ICCC 2013
Country/TerritoryIndia
CityTrivandrum, Kerala
Period13/12/1315/12/13

Keywords

  • BTX separation
  • dividing wall column
  • multivariable control
  • robust model based control

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Control and Systems Engineering

Fingerprint

Dive into the research topics of 'Robust model based control of dividing wall column'. Together they form a unique fingerprint.

Cite this