TY - JOUR
T1 - Post occupancy evaluation of school refurbishment projects
T2 - Multiple case study in the UK
AU - Ahmed, Hamad
AU - Edwards, David J.
AU - Lai, Joseph H.K.
AU - Roberts, Chris
AU - Debrah, Caleb
AU - Owusu-Manu, De Graft
AU - Thwala, Wellington Didibhuku
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/4
Y1 - 2021/4
N2 - Buildings inevitably deteriorate with time. Schools buildings are no exception and require refurbishment at times. Despite the UK Government announcing the £1 billion funding for rebuilding 50 schools over 10 years starting 2010–2021, it is common practice for builders and designers to, upon completion of a building project, move on to the next development without considering how the completed building performs. This research undertakes a post occupancy evaluation (POE) of three schools in the West Midlands, UK with specific focus on building services, viz., heating, lighting, and air conditioning and ventilation. The research adopted a mixed philosophical approach of interpretivism and post-positivism to conduct inductive reasoning. A questionnaire that collected both quantitative and qualitative primary data was distributed to the end-users of the schools. Data was analysed using the Cronbach’s alpha, one sample t-test and Kruskal–Wallis test to identify any differences between the questionnaire responses. Findings revealed that building users demanded greater control of the internal environment thus contradicting the current trend for automated ‘intelligent systems’ approaches. This research represents the first work to consider the contractor’s perspective towards developing a better understanding of client satisfaction with the school buildings. Moreover, the POE result represents a notable pragmatic advancement to knowledge that will influence the contractor’s knowledge and understanding of client satisfaction, and where to improve upon these.
AB - Buildings inevitably deteriorate with time. Schools buildings are no exception and require refurbishment at times. Despite the UK Government announcing the £1 billion funding for rebuilding 50 schools over 10 years starting 2010–2021, it is common practice for builders and designers to, upon completion of a building project, move on to the next development without considering how the completed building performs. This research undertakes a post occupancy evaluation (POE) of three schools in the West Midlands, UK with specific focus on building services, viz., heating, lighting, and air conditioning and ventilation. The research adopted a mixed philosophical approach of interpretivism and post-positivism to conduct inductive reasoning. A questionnaire that collected both quantitative and qualitative primary data was distributed to the end-users of the schools. Data was analysed using the Cronbach’s alpha, one sample t-test and Kruskal–Wallis test to identify any differences between the questionnaire responses. Findings revealed that building users demanded greater control of the internal environment thus contradicting the current trend for automated ‘intelligent systems’ approaches. This research represents the first work to consider the contractor’s perspective towards developing a better understanding of client satisfaction with the school buildings. Moreover, the POE result represents a notable pragmatic advancement to knowledge that will influence the contractor’s knowledge and understanding of client satisfaction, and where to improve upon these.
KW - Building services
KW - Construction
KW - POE
KW - Refurbishment
KW - Schools
KW - Soft landings
UR - http://www.scopus.com/inward/record.url?scp=85104974325&partnerID=8YFLogxK
U2 - 10.3390/buildings11040169
DO - 10.3390/buildings11040169
M3 - Article
AN - SCOPUS:85104974325
SN - 2075-5309
VL - 11
JO - Buildings
JF - Buildings
IS - 4
M1 - 169
ER -