Skip to main navigation Skip to search Skip to main content

Feasibility and techno-economic analysis of PV-battery priority grid tie system with diesel resilience: A case study

  • Dessalegn Bitew Aeggegn
  • , Takele Ferede Agajie
  • , Yalew Gebru Workie
  • , Baseem Khan
  • , Armand Fopah-Lele
  • Debre Markos Institute of Technology
  • University of Buea
  • Hawassa University

Research output: Contribution to journalArticlepeer-review

42 Citations (Scopus)

Abstract

Ethiopia is close to the equator and has enormous potential as a solar energy resource that has yet to be realized. The country has some small-scale diesel-based power generation, and all universities and government agencies have installed standby generator sets for supplying power when the grid is interrupted. Ethiopia is a developing nation with a significant reliance on oil imports and insufficient rural electrification, which exacerbates the problem of poverty. The increased cost of oil, frequent hard currency expenditures for oil, and exaggerated maintenance costs for the generators are the main reasons to undertake this feasibility study. As the assessments show, the annual average interruption was more than 800 h in the past five years in the Debre Markos University distribution feeder. A preliminary study on the techno-economic feasibility of the existing diesel generator set and PV system with the same rated power of 500 kW is conducted in this work. As the break-even point of the economic comparison shows, the existing diesel generator is not economically feasible as compared to the proposed PV-battery priority grid tie system due to high running and service costs. The study also shows the technical feasibility of solar energy, as the P–V and I–V characteristic curves illustrated on a single standard solar module indicate. As the economic comparison break-even point shows, the diesel-based generator set is not economical after 5 years due to the high operational and maintenance costs. As the results show, the proposed PV/Battery Priority system with a diesel generator for resilience is more environmentally friendly, reducing the carbon footprint by 94%.

Original languageEnglish
Article numbere19387
JournalHeliyon
Volume9
Issue number9
DOIs
Publication statusPublished - Sept 2023
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 1 - No Poverty
    SDG 1 No Poverty
  2. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  3. SDG 13 - Climate Action
    SDG 13 Climate Action

Keywords

  • PV priority grid tie
  • P–V and I–V characteristics curve
  • Techno-economic analysis

ASJC Scopus subject areas

  • Multidisciplinary

Fingerprint

Dive into the research topics of 'Feasibility and techno-economic analysis of PV-battery priority grid tie system with diesel resilience: A case study'. Together they form a unique fingerprint.

Cite this