Feasibility and effectiveness of heat pipe cooling in end milling operations: Thermal, structural static, and dynamic analyses: A new approach

Lin Zhu, Tien Chien Jen, Yi Hsin Yen, Xiao Ling Kong

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

In this paper, the feasibility and effectiveness of heat pipe cooling in end milling operations are investigated. A new embedded heat pipe technology was utilized to remove the heat generated at the tool-interface in end milling processes. Numerical studies involved four cases, including dry milling, fluid cooling, heat pipe cooling, and heat pipe cooling with cutting fluid supplied. The thermal, structural static, and dynamic characteristics of the end-mill were investigated using a numerical calculation with fast finite element plus solvers based on explicit finite element analysis software. The results demonstrate that the heat pipe end-mill is most feasible and effective in the actual end milling processes.

Original languageEnglish
Article number054503
JournalJournal of Manufacturing Science and Engineering
Volume133
Issue number5
DOIs
Publication statusPublished - 2011
Externally publishedYes

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Mechanical Engineering
  • Computer Science Applications
  • Industrial and Manufacturing Engineering

Fingerprint

Dive into the research topics of 'Feasibility and effectiveness of heat pipe cooling in end milling operations: Thermal, structural static, and dynamic analyses: A new approach'. Together they form a unique fingerprint.

Cite this