TY - GEN
T1 - Eaves connections of double-bay portal frames with staggered single channel cold-formed rafters
AU - Tshuma, B.
AU - Dundu, M.
N1 - Publisher Copyright:
© 2016 Taylor & Francis Group, London.
PY - 2016
Y1 - 2016
N2 - Experimental tests were performed to evaluate the structural performance of the eaves region of double-bay portal frames with staggered cold-formed rafters. This region represents the distance from the point of maximum moment at the eaves joint to the point of zero moment (contraflexure) in the rafters and columns respectively. The column and two rafter members are formed from single cold-formed channel sections, which are bolted back-to-back at the eaves joint. In order to simplify the connections the rafters are connected directly to the back of the web of the column at different levels. Particular attention was focused on the failure modes of the structures, the strength (resistance to moment) of the connection, the moment-curvature performance and the connection’s ability to form plastic hinges. In all the tested structures, the column failed by local buckling in the compression flange and web, between the upper and lower rafters. The moment-curvature graphs proved that plasticity could not be achieved in these connections.
AB - Experimental tests were performed to evaluate the structural performance of the eaves region of double-bay portal frames with staggered cold-formed rafters. This region represents the distance from the point of maximum moment at the eaves joint to the point of zero moment (contraflexure) in the rafters and columns respectively. The column and two rafter members are formed from single cold-formed channel sections, which are bolted back-to-back at the eaves joint. In order to simplify the connections the rafters are connected directly to the back of the web of the column at different levels. Particular attention was focused on the failure modes of the structures, the strength (resistance to moment) of the connection, the moment-curvature performance and the connection’s ability to form plastic hinges. In all the tested structures, the column failed by local buckling in the compression flange and web, between the upper and lower rafters. The moment-curvature graphs proved that plasticity could not be achieved in these connections.
UR - http://www.scopus.com/inward/record.url?scp=85013105016&partnerID=8YFLogxK
U2 - 10.1201/9781315641645-174
DO - 10.1201/9781315641645-174
M3 - Conference contribution
AN - SCOPUS:85013105016
SN - 9781138029279
T3 - Insights and Innovations in Structural Engineering, Mechanics and Computation - Proceedings of the 6th International Conference on Structural Engineering, Mechanics and Computation, SEMC 2016
SP - 1056
EP - 1061
BT - Insights and Innovations in Structural Engineering, Mechanics and Computation - Proceedings of the 6th International Conference on Structural Engineering, Mechanics and Computation, SEMC 2016
A2 - Zingoni, Alphose
PB - CRC Press/Balkema
T2 - 6th International Conference on Structural Engineering, Mechanics and Computation, SEMC 2016
Y2 - 5 September 2016 through 7 September 2016
ER -