TY - JOUR
T1 - Development of a sensitive and inexpensive electrochemical sensor for indigotin using poly(valine) modified carbon paste electrode
AU - Bhimaraya, Kanthappa
AU - Manjunatha, Jamballi G.
AU - Nagarajappa, Hareesha
AU - Tighezza, Ammar M.
AU - Albaqami, Munirah D.
AU - Sillanpää, Mika
N1 - Publisher Copyright:
© 2023
PY - 2023/11
Y1 - 2023/11
N2 - In this study, an electro-polymerized valine (VLN) stimulated carbon paste electrode (CPE) was used to create a straightforward, inexpensive, and renewable electrochemical sensor for accurate and selective indigotin (IGN) determination. Comparing the CPE, to the modified electrode, it exhibits excellent sensibility for the IGN oxidation-reduction reaction. Multiple techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) were utilized in this case to characterize the electrode materials. IGN was analyzed using CPE and poly(valine) modified carbon paste electrodes (P(VLN)MCPE) taking a 6.5 pH in 0.2 M phosphate buffer solution (PBS). Because it has more active spots than the CPE and a strong electrocatalytic nature, P(VLN)MCPE exhibits excellent electrochemical performance. The impact of pH, scan rate, numerous interferents, and fluctuation in analyte concentration were only a few of the important electrochemical factors that were investigated. The variation in scan rate proves that the IGN oxidation-reduction reaction on the surface of P(VLN)MCPE is as follows an adsorption-controlled pathway. The P(VLN)MCPE displays a good electrochemical nature for IGN in the 0.2 to 5.0 μM range, with a low limit of detection (LOD) is 0.0069 μM and a limit of quantification (LOQ) is 0.023 μM. P(VLN)MCPE shows good reproducibility, stability, and repeatability for the detection of IGN. Additionally, P(VLN)MCPE's analytical applicability for IGN detection in water sample was assessed with impressive recovery.
AB - In this study, an electro-polymerized valine (VLN) stimulated carbon paste electrode (CPE) was used to create a straightforward, inexpensive, and renewable electrochemical sensor for accurate and selective indigotin (IGN) determination. Comparing the CPE, to the modified electrode, it exhibits excellent sensibility for the IGN oxidation-reduction reaction. Multiple techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) were utilized in this case to characterize the electrode materials. IGN was analyzed using CPE and poly(valine) modified carbon paste electrodes (P(VLN)MCPE) taking a 6.5 pH in 0.2 M phosphate buffer solution (PBS). Because it has more active spots than the CPE and a strong electrocatalytic nature, P(VLN)MCPE exhibits excellent electrochemical performance. The impact of pH, scan rate, numerous interferents, and fluctuation in analyte concentration were only a few of the important electrochemical factors that were investigated. The variation in scan rate proves that the IGN oxidation-reduction reaction on the surface of P(VLN)MCPE is as follows an adsorption-controlled pathway. The P(VLN)MCPE displays a good electrochemical nature for IGN in the 0.2 to 5.0 μM range, with a low limit of detection (LOD) is 0.0069 μM and a limit of quantification (LOQ) is 0.023 μM. P(VLN)MCPE shows good reproducibility, stability, and repeatability for the detection of IGN. Additionally, P(VLN)MCPE's analytical applicability for IGN detection in water sample was assessed with impressive recovery.
KW - Carbon paste electrode
KW - Indigotin
KW - Valine
KW - Voltammetric analysis
KW - Water sample analysis
UR - http://www.scopus.com/inward/record.url?scp=85174465079&partnerID=8YFLogxK
U2 - 10.1016/j.heliyon.2023.e20937
DO - 10.1016/j.heliyon.2023.e20937
M3 - Article
AN - SCOPUS:85174465079
SN - 2405-8440
VL - 9
JO - Heliyon
JF - Heliyon
IS - 11
M1 - e20937
ER -