TY - JOUR
T1 - Corrigendum to “Profitability analysis of renewable energy technologies for electrification and cooking in rural areas” (Bioresource Technology Reports (2025) 30, (S2589014X25001045), (10.1016/j.biteb.2025.102122))
AU - Falama, Ruben Zieba
AU - Sun, Yanxia
N1 - Publisher Copyright:
© 2025 Elsevier Ltd
PY - 2025
Y1 - 2025
N2 - The authors regret that the below listed errors were inadvertently missed 1. In the denominator of Eq. (1) of the published manuscript (page 4) the value is 0.277778 instead of 0,277778.2. In page 5 of the published manuscript, in Eq. (5), 1 kg of charcoal corresponds to 0.65 m3 of biogas instead of 0.7 m3. Thus Eq. (5) is written as MCH = Vgc/0.65, leading to some changes in the “Results and discussion” section regarding values related to charcoal. In paragraph 2 (page 9), please consider: regarding the annual cooking fuel used for system with PV the value for charcoal is 1,771,100 kg of charcoal (corresponding to 14,717,841 kWh). In paragraph 3 (page 9), please consider: For the system using PV combined to charcoal (PV/BT/CH), the CO2 emissions is 6,110,300 kgCO2e/year. Again, in paragraph 3 please consider: the CO2 emissions reduction is 21.95 % for the PV/BT/CH system. In table 8 (page 10), regarding the column of the PV/BT/CH system, please consider Es (kWh) = 16,305,141 kWh, ECH_c (kWh) = 14,717,841 kWh, and ET = 15,804,219.7 kWh. In table 9 (page 10), regarding the column of the PV/BT/CH system, please consider MCH (kg) = 1,771,100 kg, CO2e (kgCO2e) = 6,110,300 kgCO2e, and CO2e reduction (%) = 21.95 %.3. In table 4 (page 8), Labour cost for system operation is expressed in $ (8348 $). In table 8 (page 10), Eec and ET are expressed in kWh, Vbgd and Vg_excess are in m3. In Eq (35) page 8, please consider c = (ec, bg_c, FW_c, LPG_c, CH_c). In the third paragraph of section 1.1 of the introduction (page 2), please correct the unit kgCO2/year by kgCO2e/year (54,901,840 kgCO2e/year). In subsection 2.1.1 please consider BG/Bgc instead of BG/Bg. In Eq. (38) please consider Ebg_c (Δτ).4. In table 5 (page 8), there is not Eq. (2) remove it and consider the following: Move i toward j.5. In table 6 (page 9), ρ is expressed in kg/m3 instead of m3/kg.The authors would like to apologise for any inconvenience caused.
AB - The authors regret that the below listed errors were inadvertently missed 1. In the denominator of Eq. (1) of the published manuscript (page 4) the value is 0.277778 instead of 0,277778.2. In page 5 of the published manuscript, in Eq. (5), 1 kg of charcoal corresponds to 0.65 m3 of biogas instead of 0.7 m3. Thus Eq. (5) is written as MCH = Vgc/0.65, leading to some changes in the “Results and discussion” section regarding values related to charcoal. In paragraph 2 (page 9), please consider: regarding the annual cooking fuel used for system with PV the value for charcoal is 1,771,100 kg of charcoal (corresponding to 14,717,841 kWh). In paragraph 3 (page 9), please consider: For the system using PV combined to charcoal (PV/BT/CH), the CO2 emissions is 6,110,300 kgCO2e/year. Again, in paragraph 3 please consider: the CO2 emissions reduction is 21.95 % for the PV/BT/CH system. In table 8 (page 10), regarding the column of the PV/BT/CH system, please consider Es (kWh) = 16,305,141 kWh, ECH_c (kWh) = 14,717,841 kWh, and ET = 15,804,219.7 kWh. In table 9 (page 10), regarding the column of the PV/BT/CH system, please consider MCH (kg) = 1,771,100 kg, CO2e (kgCO2e) = 6,110,300 kgCO2e, and CO2e reduction (%) = 21.95 %.3. In table 4 (page 8), Labour cost for system operation is expressed in $ (8348 $). In table 8 (page 10), Eec and ET are expressed in kWh, Vbgd and Vg_excess are in m3. In Eq (35) page 8, please consider c = (ec, bg_c, FW_c, LPG_c, CH_c). In the third paragraph of section 1.1 of the introduction (page 2), please correct the unit kgCO2/year by kgCO2e/year (54,901,840 kgCO2e/year). In subsection 2.1.1 please consider BG/Bgc instead of BG/Bg. In Eq. (38) please consider Ebg_c (Δτ).4. In table 5 (page 8), there is not Eq. (2) remove it and consider the following: Move i toward j.5. In table 6 (page 9), ρ is expressed in kg/m3 instead of m3/kg.The authors would like to apologise for any inconvenience caused.
UR - https://www.scopus.com/pages/publications/105017283704
U2 - 10.1016/j.biteb.2025.102293
DO - 10.1016/j.biteb.2025.102293
M3 - Comment/debate
AN - SCOPUS:105017283704
SN - 2589-014X
JO - Bioresource Technology Reports
JF - Bioresource Technology Reports
M1 - 102293
ER -