TY - JOUR
T1 - Amine-functionalized magnetic activated carbon as an adsorbent for preconcentration and determination of acidic drugs in environmental water samples using HPLC-DAD
AU - Akawa, Mpingana Ndilimeke
AU - Dimpe, Kgogobi Mogolodi
AU - Nomngongo, Philiswa Nosizo
N1 - Publisher Copyright:
© 2020 Mpingana Ndilimeke Akawa et al.
PY - 2020/1/1
Y1 - 2020/1/1
N2 - In the present study, a convenient and highly effective method was developed for the quantification of acidic drugs in wastewater and river water samples. Ultrasonic-assisted magnetic solid phase extraction employing magnetic waste tyre-based activated carbon nanocomposite functionalized with [3-(2-aminoethylamino) propyl]trimethoxysilane as a cost-effective and efficient adsorbent was used for the extraction and preconcentration of acidic drugs (naproxen [NAP], ketoprofen (KET) and diclofenac [DIC]). The quantification of target analytes was achieved by high-performance liquid chromatography with diode array detector. Under optimum conditions, the detection limit, quantification limit and relative standard deviation obtained for the analytes of interest ranged from 0.38 to 0.76, 1.26 to 2.54 μg L-1 and 2.02 to 4.06%, respectively. The applicability of the developed method was assessed by the spike recovery tests and the relative recoveries proved that the method is reliable for the determination of acidic drugs in wastewater. Thereafter, the method was applied successfully for the determination of NAP, KET and DIC in river water, influent and effluent wastewater.
AB - In the present study, a convenient and highly effective method was developed for the quantification of acidic drugs in wastewater and river water samples. Ultrasonic-assisted magnetic solid phase extraction employing magnetic waste tyre-based activated carbon nanocomposite functionalized with [3-(2-aminoethylamino) propyl]trimethoxysilane as a cost-effective and efficient adsorbent was used for the extraction and preconcentration of acidic drugs (naproxen [NAP], ketoprofen (KET) and diclofenac [DIC]). The quantification of target analytes was achieved by high-performance liquid chromatography with diode array detector. Under optimum conditions, the detection limit, quantification limit and relative standard deviation obtained for the analytes of interest ranged from 0.38 to 0.76, 1.26 to 2.54 μg L-1 and 2.02 to 4.06%, respectively. The applicability of the developed method was assessed by the spike recovery tests and the relative recoveries proved that the method is reliable for the determination of acidic drugs in wastewater. Thereafter, the method was applied successfully for the determination of NAP, KET and DIC in river water, influent and effluent wastewater.
KW - Acidic drugs
KW - Magnetic activated carbon
KW - Preconcentration
KW - Response surface methodology
UR - http://www.scopus.com/inward/record.url?scp=85092915862&partnerID=8YFLogxK
U2 - 10.1515/chem-2020-0162
DO - 10.1515/chem-2020-0162
M3 - Article
AN - SCOPUS:85092915862
SN - 2391-5420
VL - 18
SP - 1218
EP - 1229
JO - Open Chemistry
JF - Open Chemistry
IS - 1